Apically extruded debris and irrigants during root canal instrumentation with TruNatomy and ProTaper Gold rotary file systems


Submitted: 11 February 2021
Accepted: 11 May 2021
Published: 5 July 2021
Abstract Views: 3704
PDF: 691
Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Authors

Aim: The objective of this study was to evaluate the amount of apically extruded debris and irrigants produced by TruNatomy and ProTaper Gold in mandibular incisor root canals.

Methodology: Forty mandibular incisors were instrumented using TruNatomy (Dentsply Sirona, Maillefer, Ballaigues, Switzerland) and ProTaper Gold (Dentsply Sirona, Maillefer, Ballaigues, Switzerland) rotary systems. Apically extruded debris and irrigants during instrumentation were collected into preweighed Eppendorf tubes and were assessed with an electronic scale.  All the procedures were performed in a 35 °C hot water bath. The data were analyzed using the Shapiro-Wilk test and Mann-Whitney U test at a 5% significance level.

Results: Both NiTi file systems investigated extruded debris from the apical foramen. According to the data, the TruNatomy group extruded significantly less debris and irrigant from the apical foramen than the ProTaper Gold group (p<0.05).

Conclusions: All the instruments caused apical extrusion. The TruNatomy instruments extruded less debris and irrigants apically than the ProTaper Gold instruments.


Falakaloglu, S., Yeniçeri Özata, M., & İriboz, E. (2021). Apically extruded debris and irrigants during root canal instrumentation with TruNatomy and ProTaper Gold rotary file systems. Giornale Italiano Di Endodonzia, 35(2). https://doi.org/10.32067/GIE.2021.35.01.29